AGP3000/AST3000/LT3000/GP4000/SP5000 Cables and Adapters
Cable/adapter requirements vary depending on the device you are connecting to. Complete details can be found in the Device/PLC Connection Manual.
Cables | |||||||
Product Name |
Part Number |
Notes |
Host Side |
AGP3000 |
GP4000 |
SP5000 |
USB Transfer Cable (2m) |
CA3-USBCB-01 | USB host to host cable, for transferring data, such as screen data, between the HMI and a personal computer. | USB Type-A | USB Type-A | USB Type-A | USB Type-A |
USB Transfer Cable (1.8 m) |
ZC9USCBMB1 | Cable for transferring screen data from a PC to the GP4000 series unit. | USB Type-A | USB Mini-B | ||
Ethernet Crossover Cable (5m) |
HMI-CAB-ETH | Directly connect via Ethernet either the PC to the HMI for programming or the HMI to the PLC for communications. | RJ-45 | RJ-45 | ||
USB Cable (5m) |
FP-US00 | USB cable for the connection of peripheral equipment. | USB Type-B | USB Type-A | ||
USB Front Panel Access Cable (1m) |
ZC9USEXMB1 | Front panel adapter cable allows USB type Mini-B access through front of a panel enclosure. | USB Mini-B female | USB Mini-B | ||
CA5-USBEXT-01 | Front panel adapter cable allows USB type-A access through front of a panel enclosure. | USB Type-A Female | USB Type-A | |||
USB to Serial (RS232) Conversion Adapter (1m) |
CA6-USB232-01 | Converts a USB port to a serial port. Use with modems | D-Sub 9-pin female | USB Type-A | ||
USB to Serial (RS-422/485) Conversion Adapter | PFXZCBCBCVUSR41 | Cable for connecting a GP4000 unit (USB Type-A) with an external device (RS-422/RS-485) | D-sub 9-pin | USB Type-A | ||
DB9 Open ended Cable (5m) |
HMI-CAB-ST001 | Connects DB9 COM port with 9 open ended wires for connecting to 3rd party screw terminal devices. | 9 open conductors | COM 1 | COM 1,2 | |
RS-232C Cable (5m) |
CA3-CBL232/5M-01 | RS-232C cable connecting various hosts | D-Sub 25-pin male | COM 1 | COM 1,2 | |
RS-422 Cable (5m) |
CA3-CBL422-01 | RS-422 cable connecting various hosts and the AGP3000 *7 (plug type) | Crimped Separated Cable | COM 2 | ||
CA3-CBL422/5M-01 | RS-422 cable connecting various hosts and the AGP/AST3000/GP4000 (socket type) | Crimped Separated Cable | COM 1 | COM 2*12 | COM 1,2 | |
Allen-Bradley SLC/Contrologix Connection Cable |
HMI-CAB-ST52 (12ft) | RS-232C Cable provides direct connection to Allen-Bradley SLC5/03, 5/04, Contrologix, and Compactlogix PLCs | D-Sub 9-pin female | COM 1 | COM 1,2 | |
HMI-CAB-ST52-30X (30ft) | ||||||
HMI-CAB-ST52-50X (50ft) | ||||||
Allen-Bradley Micrologix DIN Connection Cable |
HMI-CAB-ST106 *Discontinued* |
No longer available. Please see App. Note 1183 for alternate solutions. | ||||
Emerson ROC Connection Cable |
HMI-CAB-ST809 *Discontinued* |
No longer available. Please see App. Note 1219 for alternate solutions. | ||||
Mitsubishi PLC A-Series Connection Cable (5m) |
CA3-CBLA-01 | Cable for directly connecting a Mitsubishi A Series CPU | D-Sub 25-pin male | COM 1 | COM 2*12 | COM 1,2 |
Mitsubishi PLC Q-Series Connection Cable (5m) |
CA3-CBLQ-01 | Cable for directly connecting a Mitsubishi Q Series CPU | Mini-DIN 6-pin | COM 1 | COM 1,2 | |
Mitsubishi PLC Q-Series Link Cable (5m) |
CA3-CBLLNKMQ-01 | Cable connecting to Link unit of Mitsubishi Electric's PLC Q Series | D-Sub 9-pin male | COM 1 | COM 1,2 | |
Mitsubishi PLC FX-Series Connection Cable (5m) |
CA3-CBLFX/5M-01 | Cable provides direct connection to CPU of Mitsubishi Electric's PLC FX Series | Mini-DIN 8-pin | COM 1 | COM 2*12 | COM 1,2 |
Mitsubishi PLC FX-Series Connection Cable (1m) |
CA3-CBLFX/1M-01 | Cable provides direct connection to CPU of Mitsubishi Electric's PLC FX Series | Mini-DIN 8-pin | COM 1 | COM 2*12 | COM 1,2 |
Omron PLC SYSMAC Link Cable (5m) |
CA3-CBLSYS-01 | Cable connecting to LINK unit of Omron's PLC SYSMAC | D-Sub 9-pin male | COM 1 | COM 1,2 | |
Siemens TTY Converter Cable (5m) |
CA6-CBLTTY/5M-01 | Connects a Siemens S5 series PLC. | D-Sub 15-pin male | COM 1 | COM 1,2 | |
Siemens S7 MPI Cable | ST03-A2B-MPI21-PFE | Connects a Siemens S7-200, S7-300, S7-400. For limitations, refer to App. Note 1164 | D-Sub 9-pin male | COM 1 | COM 2*12 | COM 2*13 |
CA3-MPI-PG1-PFE | MPI Communication GP4x03 only | COM 2 | ||||
CA3-MPI-PGN-PFE | ||||||
Siemens S7 MPI Cable (3.5m) |
GP3000-MPI21-PFE | Connects a Siemens S7-200 CPU215+, S7-300, S7-400. For additional information, refer to App. Note 1164 | D-Sub 9-pin male | COM 2 | ||
AGP Multi-Link Cable (5m) |
CA3-CBLMLT-01 | Cable Connects a host controller to the AGP/AST3000/GP4000 for Multi-Link (n:1) communication. *6*7 | Crimped Separated Cable | COM 1 | COM 2*12 | COM 1,2 |
GP4000 Multi-Link Cable |
PFXZCBCBML1 | Connects a host controller to the GP4000 for Multi-Link (n:1) communication. | COM 2*12 | |||
AGP 2 port Adapter Cable (5m) |
CA3-MDCB11 | Connects Mitsubishi PLC to the AGP3000 using the 2 port adapter II (RS-422) *6*7 | COM 1,2 | COM 2*12 | COM 1,2 | |
GP4000 2 port Adapter Cable |
PFXZCBCBMD1 | Connects Mitsubishi PLC to the GP4000 using the 2 port adapter II (RS-422) | COM 2*12 | COM 1,2 | ||
AGP3000H Connector Cables (3m, 5m, 10m) |
GP3000H-CBLH-10M | AGP3000H Cable, Hard Type, 10M | Without connector | |||
GP3000H-CBLHD-10M | AGP3000H Cable, Hard Type, 10M | With connector | ||||
GP3000H-CBLS-*M | AGP3000H Cable, Soft type ("*" is changed with length: 3m, 5m, 10m. Example: GP3000H-CBLSD-3M is 3 meters) |
Without connector | ||||
GP3000H-CBLSD-*M | AGP3000H Cable, Soft type ("*" is changed with length: 3m, 5m, 10m. Example: GP3000H-CBLSD-3M is 3 meters) |
With connector | ||||
DVI Cable | FP-DV01-50 (5m) | For outputing image signal from host to GP | ||||
FP-DV01-100 (10m) | ||||||
DVI-RGB Cable | CA7-CBLCVRGB-01 | For converting DVI-A to RGB | ||||
USB Cable for RGB Input Unit (5m) | CA9-USBAMB/5M-01 | USB cable for RGB Input Unit touch panel operation (Host-Slave: Mini-B) | ||||
USB Cable anti-disconnect holder (RGB Input Unit Side-Mini-B) | CA9-USBATRGB/MB-01 | Disconnecting prevention clamp for the RGB Input USB Cable (2 pcs/set) | ||||
RGB Cable (4.5 m) | FP-CV02-45 | For outputing image signal from host to GP |
Adapters | |||||||
Product Name |
Part Number |
Notes |
Host Side |
AGP3000 |
GP4000 |
SP5000 |
COM Port Conversion Adapter |
CA3-ADPCOM-01 | Pin Conversion Adapter. Connects AGP3000 COM 2 cables and options to COM 1. | D-Sub 9-pin female | COM 1 | COM 2*12 | COM 1,2 |
On-line Adapter | CA4-ADPONL-01 | Polarization adapter for use when connecting RS-422/485.*7 | D-Sub 9-pin female | COM 2 | ||
9-pin-to-25-pin RS-232C Conversion Cable | CA3-CBLCBT232-01 | Cable for converting a RS232 D-sub 9-pin plug to a D-sub 25-pin socket *11 | D-Sub 25-pin female | COM 1 | COM 1 | COM 1,2 |
9-pin-to-25-pin RS-422 Conversion Cable | CA3-CBLCBT422-01 | Cable for converting a RS422 D-sub 9-pin socket to a D-sub 25-pin socket. Adapts legacy GP RS422/RS485 cables. | D-Sub 25-pin female | COM 2 | ||
PFXZCBCBCVR41 | Cable for converting a RS422 D-sub 9-pin plug to a D-sub 25-pin socket. Adapts legacy GP RS422/RS485 cables. | D-Sub 25-pin female | COM 1 | COM 2*12 | COM 1,2 | |
Terminal Block RS422/485 Conversion Adapter AGP3000 COM 2 |
CA3-ADPTRM-01 | RS-422 Terminal adapter D-sub 9-pin socket to screw terminals.*6*7 | Terminal block | COM 2 | ||
Terminal Block RS422/485 Conversion Adapter 9-pin male COM ports |
PFXZCBADTM1 | RS-422 Terminal adapter D-sub 9-pin plug to screw terminals | Terminal block | COM 1 | COM 2*12 | COM 1,2 |
Siemens COM Port Conversion Adapter | CA3-ADPSEI-01 | Adapter for SIEMENS MPI when using Profibus connector and cabling w/ AGP3000. | D-Sub 9-pin female | COM 2 | ||
Mitsubishi PLC A,QnA,FX Series 2 port adapter II |
GP070-MD11 | Interface unit using Mitsubishi Electric's PLC A/QnA/FX Series at the same time. | ||||
AGP3000H Conversion Adapter | AGP3000H-ADPCOM-01 | For interfacing with a RS-232C/RS-422/RS-485 serial interface output (D-Sub) | ||||
RS-232C Isolation Unit |
CA3-ISO232-01 | Unit for electrically isolating a serial interface signal from the GP internal current (RS-232C and RS-422 are switchable). | COM 1 | COM 1 | COM 1,2 | |
RS-485 Isolation Unit |
CA3-ISO485-01 | Unit for electrically isolating a serial interface signal from the GP internal current (RS-422 and RS-485 are switchable). | COM 2 | |||
CF Card Adapter | GP077-CFAD10 | Adapter using CF card with a PC's PCMCIA slot. | ||||
Pin Jack Adapter | GP077-SDAD10 | Adapter for converting the audio output section to the AUX connector to a pin jack |
*6 | When connecting to COM 1 and male COM 2 ports a conversion adapter (CA3-ADPCOM-01) is required. |
---|---|
*7 | CA4-ADPONL-01 Online adapter is required for these cases: 1:1 communication, For use in 1:N, N:1 (MPI only), N:N communication terminal (1 unit, or potentially up to 2 units can be used.) For AGP3000 COM 2 only. Not for AGP3302B and AGP3200. |
*8 | For termination, set switch to "ON". |
*11 | A commercially available 9-25 pin serial port adapter can be used. |
*12 | COM 1 on LT3300 & GP4000M. (Not for AST3211A, GP4x03, or AST3302B) |
*13 | SB5B10 Power Box only |
Last Updated: 2015.10.21 Please note: Part numbers may be discontinued without notice. Please contact your local Pro-face authorized distributor for current pricing and availability. |