12.6.1
Procedure - Changing the Window on All Screens
The Global Window changes depending on the value stored in a
word address (for example, D117).
-
From [System Settings], point to [Display Unit] and
open the [Mode] tab.

-
From [Global Window Operation], select
[Indirect].

-
Set the [Data Type].
-
Select the [System Area] tab.

-
In [System Area Device], select the appropriate
device/PLC that uses the system area. In [System Area Start
Address], define the top address (D100).
-
Select the following
check boxes: [Enable System Data Area], [Window Control], [Window
Screen], and [Window Display Position].

The Global Window (Indirect designation) settings are complete.
When bit 0 of the Window Control Address (example, D116)
specified in [System Area Device] turns ON, the Window displays.
When the Window address (example, D117) value changes, the screen
changes. When the value of the display coordinate address (for
example, X-coordinate is D118, Y-coordinate is D119) changes, the
Window position changes.
|