RFAF005
|
Select device name
|
The monitor was started without [Connection
Device Name] selected in [Device View]. Select a connection device
name in [Device View].
|
37.20.1.7
Standard Template HTML - Main Frame / [Device View] Page
|
RFAF006
|
Enter device address
|
The monitor was started without [Device
Address] selected in [Device View].
Select [Device Address] in [Device View].
|
37.20.1.7
Standard Template HTML - Main Frame / [Device View] Page
|
RFAF007
|
Select access points
|
The monitor was started without [Access Points]
selected in [Device View]. Select [Data Type] in [Device View].
|
37.20.1.7
Standard Template HTML - Main Frame / [Device View] Page
|
RFAF008
|
Select data type
|
The monitor was started without [Data Type]
selected in [Device View]. Select [Data Type] in [Device View].
|
37.20.1.7
Standard Template HTML - Main Frame / [Device View] Page
|
RFAF009
|
Select update cycle
|
The monitor was started without [Update Cycle]
selected in [Device View]. Select [Update Cycle] in [Device
View].
|
37.20.1.7
Standard Template HTML - Main Frame / [Device View] Page
|
RFAF010
|
Insufficient memory
|
No Memory is set. Forcibly transfer the system
using GP-Pro EX. If this error still occurs despite forciby
transferring the system, reduce the screen data
capacity.*1
|
34.11.1 Transfer
Settings Guide
|
RFAF011
|
Invalid request
|
The cause of this error may be that the URL was
edited and an invalid request was sent. Transfer the standard HTML
template again using [Site Transmission] in [Transfer Tool].
Alternatively, you can run forced transfer of the system from
GP-Pro EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF024
|
Invalid URL
|
The cause of this error may be that the URL was
edited and an invalid request was sent. System Settings
Make sure that the folder specified in the Web folder of [Remote
Monitoring Settings] exists in the CF card or USB memory.
Alternatively, transfer again the standard HTML template using
[Site Transmission] in [Transfer Tool], or run a forced transfer of
the system from GP-Pro EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF026
|
Cannot open URL
|
The cause of this error may be that the URL was
edited and an invalid request was sent. System Settings
Make sure that the folder specified in the Web folder of [Remote
Monitoring Settings] exists in the CF card or USB memory.
Alternatively, transfer again the standard HTML template using
[Site Transmission] in [Transfer Tool], or run a forced transfer of
the system from GP-Pro EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF028
|
Cannot stat page for URL
|
The cause of this error may be that the URL was
edited and an invalid request was sent. System Settings
Make sure that the folder specified in the Web folder of [Remote
Monitoring Settings] exists in the CF card or USB memory.
Alternatively, transfer again the standard HTML template using
[Site Transmission] in [Transfer Tool], or run a forced transfer of
the system from GP-Pro EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF030
|
Missing form name
|
The cause of this error may be that the path
after /goform/ was specified incorrectly and accessed. Transfer the
standard HTML template again using [Site Transmission] in [Transfer
Tool] or run a forced transfer of the system from GP-Pro
EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF031
|
Form (*****) is not defined. Form Name:
*****
|
The cause of this error may be that the path
after /goform/ was specified incorrectly and accessed. Transfer the
standard HTML template again using [Site Transmission] in [Transfer
Tool] or run a forced transfer of the system from GP-Pro
EX.*2
|
34.11.1 Transfer
Settings Guide
|
RFAF040
|
Access Denied. Wrong Password
|
The password may be incorrect. Enter the
correct user ID and password. Also check if settings such as
whether only the password is used or whether both the user ID and
password are used are correct.*2
|
—
|
RFAF041
|
Access to this document requires a password
|
The cause of this error may be that the
document was accessed via a new window and the password is
incorrect. Enter the correct user ID and password. Also check if
settings such as whether only the password is used or whether both
the user ID and password are used are correct.*2
|
—
|
RFAF042
|
Access to this document requires a User ID
|
The cause of this error may be that the
document was accessed via a new window and the user ID is
incorrect. Enter the correct user ID and password. Also check if
settings such as whether only the password is used or whether both
the user ID and password are used are correct.*2
|
—
|
RFAF049
|
Cannot open template file
|
The standard HTML template is deleted. Make
sure that the folder specified in the Web folder of [Remote
Monitoring Settings] in the System Settings window exists in the CF
card or USB memory. Alternatively, transfer again the standard HTML
template using [Site Transmission] in [Transfer Tool], or run a
forced transfer of the system from GP-Pro EX.*1
|
37.20.2 System
Settings - Display Unit - Remote Viewer Settings Guide
|
RFAF051
|
Failed to get device address
|
An incorrect [Device] is set. Set the correct
[Device].
|
—
|
RFAF052
|
Failed to read device
|
An attempt was made to read the device that is
not communicating with the connection device. Set the correct
[Device]. Alternately, make sure that the Display and connection
device are correctly connected.
|
—
|
RFAF053
|
Failed to write device
|
An attempt was made to write the device that is
not communicating with the connection device. Set the correct
[Device]. Alternately, make sure that the Display and connection
device are correctly connected.
|
—
|
RFAF054
|
Entered data is not consistent with Data
Type.
|
Data was written that differs from the data
type set in [Data Type]. Enter the correct data.
|
—
|
RFAF055
|
Entered data is too much.
|
Data beyond the limit was written to the set
[Data Type]. Enter the correct amount of data.
|
37.10.3
Operation - Displaying and Editing Addresses Via Web Server
|
RFAF056
|
Enter data.
|
Blank data was entered. Enter the correct
amount of data.
|
—
|
RFAF057
|
In the server settings [Write Web Server Data]
is disabled. This operation will not run.
|
To enable writing, select [Security] -
[Passwords] - [Set Security Level For Each Feauture] from [Common
Settings] and uncheck [Disable] for [Write Web Server Data].
|
23.9.1.1 Password
Settings
|
RFAF064
|
Failed to read alarm information
|
The cause of this error may be that alarm
information is not set and the alarm list is collected. Check alarm
settings using GP-Pro EX.*1
|
Chapter 19 Alarm
|
RFAF065
|
Executing other request
|
SRAM is being accessed by the display unit.
Wait for several minutes and try updating again.*1
|
—
|