Check the settings of cables, communication
speed, input/output sizes, and master (scanner). Please check the
LED status for details.
Example, Network Communication Error, LED Status:
[0x04]*1
The following information is displayed in *1.
Error No.
Network LED
Module LED
Description
0x00 to 0x04
Does not light up
Flashing (Green)
Indicates any of the following conditions: No
electricity is supplied on the network cable, a cable is not
connected or the configuration (including settings) has not been
set.
0x04
Does not light up
Lit (Green)
Indicates any of the following conditions: No
electricity is supplied on the network cable, a cable is not
connected or the baud rate has not been properly set.
0x04 to 0x05
Flashing (Green)
Lit (Green)
Indicates any of the following conditions: This
slave has not been set on the network or the configuration has not
been properly set. Confirm the slave number.
0x05
Lit (Green)
Lit (Green)
The master is in stop mode.
0x06
Lit (Red)
Lit (Green)
Check the network settings. The baud rate
setting is incorrect or, some settings may be overlapping (for
example, slave setting).