Select [D-Script/Global D-Script] to use the "SIO Port
Operation" function, which communicates using a serial port for
D-script or Global D-script. Select [Extended Script] to use
extended scripts.
Select a port for scripts from [COM1], [COM2] or [USB-SIO].
Configure communication settings.
Communication Settings
Type Select the communication method from [RS232C], [RS422/485
(4wire)], or [RS422/485 (2wire)].
Communication Speed
Select a communication speed from [2400], [4800], [9600],
[19200], [38400], [57600] or [115200].
Data Length
Choose the communication data length from [7 bit] or [8
bit].
Parity
Select the communication parity bit from [None], [Odd], or
[Even].
Stop Bit
Choose the communication stop bit length: [2 bit] or [1
bit].
Flow Control
If the communication method is [RS232C], select the
communication control method from [None], [RTS/CTS] or [ER
(DTR/CTS)].
When [Port] is set to [USB/SIO], the setting becomes [None].
5V Power Supply
If the communication method is [RS232C], designate whether or
not to specify the 5V power supply. Only set it to [Enable] if the
connected device requires a power supply. If a 5V power supply is
not needed and you select Enable, damage can occur to the connected
device or the display unit. Confirm the specifications of the
connected device and cable before setting this.