System Settings
Configures the system settings for logic features.
Fixed Scan Time/CPU Scan Percentage
Selects the mode for logic scan time.
You can configure the time of each logic
scan. The settings range from 10 ms to 2000 ms.
30.13.3.2
Logic Scan Time, Fixed Scan
You can configure the CPU utilization of
logic scans. The settings range from 10% to 50%.
30.13.3.2
Logic Scan Time, CPU Scan Percentage
WDT (Watchdog Timer) Settings
You can configure the monitoring time for the logic scan time.
An error occurs if the logic scan time exceeds the WDT (Watchdog
Time).
The settings range from 100 ms to 3000 ms.
>>Extended / <<Basic
Click [>>Extended] to specify the [Address Refresh]
speed.
Logic
Click [Retentive Settings] to display the [Retentive Settings]
dialog box.
The retentive/volatile points can be specified for symbol
variables in [Variable Format]. The retentive/volatile ranges can
be specified for symbol variables in [Address Format].
30.14 Settings
Guide
Run at Start Up
Select an action for the display to perform when it starts
up.
Logic Program Operation
Select the logic program status: [Run] or [Stop].
External Equipment Operations
Select the PLC/device operation state: [Synchronous] or
[Asynchronous].
Exclude External I/O
Select whether to enable input/output from the I/O unit from
[Enable] or [Disable].
Minor Errors
On minor errors, select the logic program operation, [Continue]
or [Stop].