Address Type
Designate the address to operate the state from [Bit Address] or
[Word Address].
Bit Address (1 to 4) /Word Address
Set up an address. The lamp display will change depending on the
bit status of the address designated here and the [State Switch
Condition].
Number of States
Set the number of display states. The range will differ
depending on the [State Switch Condition] and whether a Bit Address
or Word Address is set.
For [Change Condition by Bit]: 3 to 5
For [Change Condition by Bit Combination]: 2 to 16
For [Change Condition by Bit]: 3 to 17
For [Change Condition by Bit Combination]: 2 to 256
State Switch Condition
When the [Number of States] is 3 or more, select the condition
that will change the status.
This can be set for either [Bit Address] or
[Word Address]. The status is judged by which bits are ON.
This can only be set for [Bit Address]. The
status is judged by the combination of bits that are ON from Bit
Address 1 to 4.
Available when [Word Address] is selected.
The state is defined by the value of the bottom eight bits in the
word address.