Enable Operation Log Function
Specifies whether to use the Operation Log feature or not
SRAM Records
Select the number of times to save to SRAM from 100, 200, 300,
400 and 500.
Operations to Log
Select the functions for Operations to Log from [Bit Switch],
[Word Switch], [Change Screen Switch], [Special Switch], [Selector
Switch], [Data Display], [Sampling Data Display], [Show CSV],
[System Menu], [Start], [Offline], and [Change Language].
Save Data
Save in
Select [CF Card] or [USB Storage] as the [Save in] location when
outputting the Operation Log to a CSV file, or when exceeding the
number of entries that can be saved in SRAM.
Record Status Address
Specifies the address that confirms the write status for saving
to CF Card or USB Storage.
While outputting the operation log file, the
Transferring bit turns ON. When the file output is complete, the
Transferring Completion Bit turns ON.
The error status indicates the following conditions.
Bit 12 to 15
|
Description
|
Introduction
|
0000
|
Completed Successfully
|
When the backup process is completed
successfully.
|
0100
|
No CF Card or USB Storage
|
When a CF Card/USB storage is not inserted
while backing up, or the CF Card hatch is open.
|
0101
|
CF Card/USB Storage Write Error
|
Occurs when the CF Card/USB storage device does
not have sufficient free space for backing up or when it is removed
during writing
|
0111
|
CF Card/USB storage error
|
CF Card/USB storage is not formatted, or some
other error
|
Save Mode
Sets actions when saving operation logs.
When [New] is selected, a new CSV file will
be created.
When [Append] is selected, data is added to the existing CSV
file.
Specifies an address to change the action for
saving data. When the specified address turns OFF, New is selected.
When the address turns ON, Append is selected.
Operation Trigger
Specifies whether or not to save at a specified timing when you
want to save the operation log at a given timing.
Retain Control Bit Address
Turn ON the designated Bit to start writing in the CF Card or
USB storage.
Operation when there is insufficient space
Specifies the operation when there is not enough space in the CF
Card or USB storage.
Stop outputting to the file of the operation
log at the "Save in" location. When the next operation is
conducted, recording of the operation log completely stops, and
nothing is recorded.
Delete the oldest file that is saved in the
CF Card or USB storage, and save the data in SRAM.
CSV File Format Settings
Set the Display Format when saving to CSV file.
Date
Select the display format for dates, from mm/dd/yy
(month/day/year), mm/dd (month/day), yy/mm/dd (year/month/day),
dd/mm/yy (day/month/year).
Time
Select the time display format as either 12:00 or 24:00.
Language
Select the language format from Japanese, languages that support
ASCII, Chinese (Traditional), Chinese (Simplified), Korean,
Cyrillic, and Thai.
Append value to log
While recording the operation log, set whether to obtain the
values stored in the specified Data Word Address.
-
If [Save Mode] [Direct] [Append] is selected,
and settings in [Append value to log] are changed, when the project
is transferred and logging starts, two groups of data will exist in
the same file - data with values and data without values. If you do
not want to have two data sets, before transfer delete the
operation log file in the external storage or rename the folder
where data is being saved.
Update Data Value
Sets a time to obtain Data Word Address values.
Values are acquired every time a record
operation log operation is performed on the target.
When the Trigger Bit Address turns ON, data
will be acquired again.
Trigger Bit Address
In [Update Data Value], when [Trigger] is selected, set the bit
address that will trigger reading data.
Data Value
Sets the type of Data Value to acquire from [Numeric Value] and
[Text].
Numeric Value
Data Word Address
Sets the Word Address to store values to be read at recording
the operation log.
The end of an address is automatically displayed according to
the [Number of Characters] setting.
Data Type
Select the [Data Word Address] data type. Choose from 16 bit
Dec, 16 bit Hex, 16 bit Oct, 16 bit BCD, 16 bit Bin, 32 bit Dec, 32
bit Hex, 32 bit Bin, or 32 bit BCD. The output format for each data
type is as follows.
Data Type
|
Signed +/-
|
Range
|
Text
|
Setup not possible
|
You can use up to 32 single-byte
characters.
|
16 Bit Dec
|
None
|
0 to 65535
|
Enable
|
-32768 to 32767
|
32 Bit Dec
|
None
|
0 to 4294967295
|
Enable
|
-2147483648 to 2147483647
|
16 Bit Hexadecimal
|
Setup not possible
|
0 to FFFF(h)
|
32 Bit Hexadecimal
|
Setup not possible
|
0 to FFFFFFFF(h)
|
16 Bit Oct
|
Setup not possible
|
0 to 177777(o)
|
16 Bit BCD
|
Setup not possible
|
0 to 9999
|
32 Bit BCD
|
Setup not possible
|
0 to 99999999
|
16 Bit Bin
|
Setup not possible
|
0 to 1111111111111111
|
32 Bit Bin
|
Setup not possible
|
0 to 11111111111111111111111111111111
|
Sign +/-
Select whether to display negative values. Select when the data
type is 16 bit Dec or 32 bit Dec.
Text
Data Word Address
Sets the range of Word Addresses to store values to be read when
recording the operation log.
Number of Characters
Sets the number of characters to acquire from 1 to 32
single-byte characters.