25.6.3 Operation -
Automatic Save
Save data from Sampling Group1 as file name "SA00000.csv" in the
CF Card.
-
In D301, store the File 0.
-
Write the command "0020h" to D300. If the display
unit enters the Auto Save mode normally, the status "2000h" will be
written from the display unit to D300.
-
When data is sampled for the designated
Occurrences, the CSV data is exported to the CF Card.
"SA00000.csv" is created in the CF Card's "SAMP01" folder.
-
When data is sampled for the designated Occurrences
again, that period's CSV data is automatically exported and added
to the existing "SA00000.csv" file in the "SAMP01" folder.
While D300 is "2000h" the Auto Save mode will continue.
-
Write the command "0021h" to D300, and the auto
save mode ends. When the display unit ends Auto Save mode, 0000h is
written to D300.
File Save
For example, Sampling Occurrences = 4
When Auto Save mode ends, even if there is content still on the
way to the display unit (when the current sampling cycle has not
completed), sampling data up to that point is written to the CF
Card.
Also, when starting or resuming Auto Save (when you write an
Start Auto Save command), sampling data in the display unit is
written to the CF Card from the start data (the oldest data),
regardless of the previous data save status.
Auto Save Exiting and Resuming - File
Save
For example, Sampling Occurrences = 4
Auto Save Exit
Auto Save Resume
|