Feature
|
Difference
|
Switches
|
-
AUX Output cannot be used.
-
Special switches related to security, resetting,
offline or other unsupported features cannot be used.
-
If switches overlap, or multiple switch functions
are set up, operations may differ from the display unit.
|
Sampling Display
|
|
Alarm feature
|
-
The Sub Display feature may be executed at an
unexpected time by operation on the display unit even when the
alarm display unit is not displayed.
-
Alarm information cannot be cleared by external
operation.
-
Display contents may be displayed differently
from the display unit (time information, active alarm status, and
so on.) Touching the [Screen Update] button will update the
contents by re-acquiring the alarm information.
-
You cannot save alarm information.
-
You cannot perform [Acknowledged] or [Clear]
operation.
-
You cannot perform [Alarm Number Acquisition]
operation.
|
Logic Programing
Global D-Script
Extended Script
|
You can review the results processed on the
display unit, but the results of drawing are not reflected.
|
D-Script
|
This feature is enabled in Synchronous Mode.
However, the results of drawing are not reflected.
This feature may be executed even in
Asynchronous Mode when the same screen is displayed.
|
Trigger Action
|
-
This feature is executed in Asynchronous Mode
when the same screen is displayed. In this case, changing screens
on the display unit does not change screens in GP-Viewer EX.
Therefore, execution of [Start Application] or [Exit WinGP] cannot
be confirmed by GP-Viewer EX, so do not perform such operations
from GP-Viewer EX.
-
This feature is enabled in Synchronous Mode.
However, the results of drawing are not reflected.
|
Screen Capture
|
|
Error
|
-
Displays errors on both the display unit and
GP-Viewer EX.
-
All errors are acquired at first and then the
information is updated at a frequency set in GP-Viewer EX. Point to
[Change setting] and select [Automatic update frequency of
information].
-
Errors that are restored will not disappear. Such
errors disappear only when the screen is changed.
|
Data Display
|
|
Historical Trend Graph
|
|
Data Block Display Graph
|
|
XY Historical Scatter Graph
|
|
XY Block Display Scatter Graph
XY Historical Scatter Graph Normalization
|
-
When quickly changing the control word using
D-Script or a PLC with ladder logic on the display unit, server
operations may not be detected.
-
In Asynchronous Mode, when updating the graph,
its Display Completion bit does not turn ON. Therefore, the control
word cannot be returned to 0 on the display unit. Prior to
updating, create a switch that returns the control word to 0.
|
Bulletin Message
|
-
When you perform a display/hide operation
continuously, display contents may not be synchronized with the
display unit.
-
In order to update the message, clear the message
and display it again.
-
Display Completion bit cannot be used.
|
Recipes
|
|
File Manager
|
|
LS Area
Memory Link
|
-
You cannot write data in the Special Relay Area
(LS2071 to LS2074, LS2078 to LS2095) from the Viewer.
-
Write operation into Special Relay Area and
Extend System Area is not supported.
|
Security Level Clear
|
-
To change or clear the level, from the Menu,
point to Feature, and select Change Security Level or Change User
ID.
You can set the security level to 0 if you leave the user
ID/password field blank and press the OK button. (This cannot be
completed when the security is set for reading Viewer data.)
|
Standby Mode
|
|
Japanese FEP (Help)
|
|
Cursor Information Storage Address
Status Address
Search Status Address
|
|
Operation Log
|
|
Web Server and FTP Features
|
|
Monitor
|
|
Remote PC Access
|
|
Printing feature
|
|
Transfer Project File
|
|
Monitor
|
|
2-color Backlight Switching
|
|
Brightness and Contrast
|
|
Offline mode
|
|
Bar Code Reader
|
|
Modem
|
|
Hand-held Display Unit Function Keys
|
|
Playing Movies
|
|
Image Sensor Display
|
|
Others
|
|