Select an address to verify the transfer state and result status
during the transfer.
Transfer Status Address
Set the address where the transfer status and result are
stored.
Error Codes (Results reflected in the error
status bits)
0
Completed Successfully
Transfer completed successfully.
1
Reserved
—
2
No Transfer Condition Number
For transfer, the Condition Number that
corresponds to the specified File Number (GROUP NO) does not
exist.
3
Internal Device Range Error
When transferring from the CF card/USB storage
to device/PLC, and when the transfer start address is specified as
an internal device address, tried to transfer data that exceeds the
internal device address range.
4
No CF Card or USB Storage / USB Storage
Error
The CF Card/USB storage is not inserted in the
display unit, or the CF Card cover is not closed.
USB storage is either corrupted or not formatted correctly.
5
Read Error
When transferring from the CF card/USB storage
to the device/PLC, failed to read data on the CF card or USB
storage device.
6
Write Error
When transferring from the device/PLC to CF
card/USB Storage, failed to write to the CF Card or USB Storage.
There may not be enough available space.
7
CF Card Error
CF card is not recognized.
CF card is either damaged or formatted incorrectly.
8
Reserved
—
9
Reserved
—
10
Reserved
—
11
No Condition
Without the [Enable Data Transmission Feature]
settings, a CSV file tries to display on the CSV display from a CF
Card/USB storage.
12
Write Error
Data writing from CF Card/USB storage data
transfer failed on the PLC.
13
Read Error
Data reading from CF Card/USB storage data
transfer failed on the PLC.
Manual Transfer Timing Chart
Touch the transfer switch and the [Transfer Status Address]
Transferring bit (bit 0) turns ON. When a data transfer is
completed successfully, the Transferring bit turns OFF and the
Transfer Completion bit (bit 1) turns ON. After confirming that the
transfer is completed, turn the Transfer Complete Bit OFF.
The Transfer Complete Flag (bit 1) is not
turned OFF automatically. Turn it OFF from the device/PLC.