31.5.9.6 Output Status
and Output Completion Status of Normal Pulse Output - Normal Pulse
Output (LT Series)
This function shows the normal pulse output state and
completion. The pulse output flag shows the output state under the
CH special I/O state in the system variable (#L_ExIOSpCtrl). If the
flag is ON, the output is ON. If the flag is off the output is OFF.
Furthermore, if the completion flag of the setting pulse shot
output is ON, the output has been completed. If the flag is OFF,
the output has not been completed. The watch bit will differ,
depending on the CH to which you allocate the pulse output.
After the defined pulse output completion flag changes from OFF
to ON, the timing of the change is set as when the corresponding
CH's special I/O control pulse output flag changes from ON to OFF
(start to stop).
#L_ExIOSpCtrl
If the start bit of the CH (0 bit) is 1, the output is ON. If it
is 0, the output is OFF.
Furthermore, if the 2nd bit is 1, the set pulse shot has been
output successfully.
|