While the instruction is in operation and the
parameter read has been completed
If no error has occurred (refer to the following
notes).
Disabling condition
While the instruction is in operation and when it
has been confirmed that the parameter read completion flag is
cleared.
(Parameter read request is canceled and the parameter read
completion flag is cleared.)
*When disabled, the operand D1 is cleared to 0.
Notes
While executing the instruction, any parameter
reads are monitored. If it is being read, an error occurs and no
process will be performed.
When the operand D1 cannot be recognized in the
instruction, an error occurs.
When executing the instruction using the pulse
(for example, PT instruction), you need to turn the instruction OFF
and then turn it ON to execute it again.
When the instruction is executed, it will be in
operation.
If the instruction is in operation, the
instruction will be executed continuously regardless of the
enabling/disabling condition.