Double-click the PLSY instruction to display the following dialog box. In the following dialog box, specify each of the settings.
For details on the special I/O of the LT, refer to the following. 31.5 Controlling External I/O with LT
Setting
Operand
Description
Setting Range
CH
S1
Specify the channel number mapped to the pulse output for the Acceleration/deceleration pulse table.
CH1 - CH4
Output Pulse Count
S2
Specify the number of pulse outputs for the Acceleration/deceleration pulse table. The value specified here is stored in #L_PLS*_NUM.
Numeric Value 0 to 2147483647
Variable Integer variable only
Output frequency
S3
Specify the Output Frequency (Hz) for the Acceleration/deceleration pulse table. The value specified here is stored in #L_PLS*_LHZ.
Numeric Value 10 to 65000
Acceleration/Deceleration time
S4
Specify the Acceleration/Deceleration Time (ms) for the Acceleration/deceleration pulse table. The value specified here is stored in #L_PLS*_ACC.
Numeric Value 0 to 65535
Initial Output Frequency
S5
Specify the Initial Output Frequency (Hz) for the Acceleration/deceleration pulse table. The value specified here is stored in #L_PLS*_SHZ.
D1: Instruction Status
D1
Specify the integer variable for storing the status of instruction execution.
Integer variable only