Double-click the HSC instruction to display the following dialog box. In the following dialog box, specify each of the settings.
For details on the special I/O of the LT, refer to the following. 31.5 Controlling External I/O with LT
Setting
Operand
Description
Setting Range
CH
S1
Specify the channel number to which the high-speed counter is assigned.
The high-speed counter for the channel number specified here is started.
CH1 - CH4
Synchronize Output
S2
Specify the mode for the high-speed counter (Synchronize Output On/Off). The value specified here is stored in the control part of #L_ExIOSPCtrl.
Constant 1 (Synchronize Output Off) or 3 (Synchronize Output On)
Variable Integer variable only
D1: Instruction Status
D1
Specify the integer variable for storing the status of instruction execution.
Integer variable only