Text File Number
Set a text file number for the text from 1 to 8,999.
Start Row Bit Address
Set the start bit address to store the text display's start row
specification data. You can set a bit address or a word address to
specify bits.
The display start row is determined by the data stored in the
range of the start row to the bit specified in [Number of Bits] and
the [Rows Scroll].
Number of Bits
Sets how many bits, from the [Start Row Bit Address], are used
for Display Start Row Specification. Select a value from 1 to 16.
The number of bits to use will differ depending on the specified
[Rows Scroll].
For example, 12 rows of text will be scrolled by 4 rows each
time = using 2 bits
Because the number of bits used is set from the Display Start
Row Specification data, the empty portion of the Reserved Area can
be used for other purposes.
For example, Start Row Bit Address = D100 8 bit, Number of Bits
= 4
-
When setting the [Number of Bits], please
ensure that the allocated bits are in one word. Even if the number
of bits is set to span across two words, only the address specified
in [Start Row Bit Address] will be allocated as the Display Start
Row.
For example, Start Row Bit Address = D100 12 bit, Number of Bits
= 10
Rows Scroll
Set the number of rows the display scrolls from 1 to 256 when
the Start Row data changes.
Display Start Row = Rows Scroll (Display
Start Row data -1) +1
For example, [Display Rows] = 4, [Rows Scroll] = 4
Display Start Row data = 1 Display Start Row
= 1
Display Start Row data = 2 Display Start Row
= 5
Display Start Row data = 3 Display Start Row =
9
If the Display Start Row is "0", the text does not display, and
the Message Display's Display Area is shown with a transparent
color.
Text File Number Word Address
Set the address where the text file number to display is stored.
The text with the number stored in this address displays.
Data Type
Select the data type of the text file number to be stored in
[Address].
Specify Start Row
Choose how the text's Start Row is specified.
Specify a set constant as the Display Start
Row.
Specify the address where the display start
row is stored.
Constant
Desired text displays starting from fixed lines.
Start Row
Set a number for the text's Display Start Row from 1 to 512.
When the start row does not exist, the operation is ignored. The
previously displayed rows remain.
Address
Displays desired text starting from various rows.
Start Row Address
Set the address of the word address that stores the text's
Display Start Row. The Display Start Row is decided by the data
stored in this field and by the [Rows Scroll].
When the start row does not exist, the operation is ignored. The
previously displayed rows remain. The display is cleared when the
Display Start Row is set to "0".
Data Type
Choose the format for the text's Display Start Row.
Rows Scroll
Set the number of rows the display scrolls from 1 to 256 when
the Start Row data changes.
Display Start Row = Rows Scroll (Display
Start Row data -1) +1
For example,
[Display] tab [Display Rows] = 4, [Rows
Scroll] = 4
Display Start Row data = 1→Display Start Row
= 1
Display Start Row data = 2→Display Start Row
= 5
Display Start Row data = 3→Display Start Row
= 9
If the Display Start Row data is "0", the text does not display,
and the Message Display's Display Area is shown with a transparent
color.