Configure settings to change the line color when values move
outside of a set range.
When [Show Scale] is set, Alarm cannot be
used.
Channel Number
Select the Channel to configure Alarm.
Alarm Settings
Select to change the color when the value moves outside of a set
range.
This cannot be set if the [Fill Below Line]
option is set in the Detail Settings on the Color tab.
Upper Limit/ Lower Limit
Set the Alarm Display range from 0 to 100 (if [Display Sign +/-]
is selected, the range is from -100 to
100).
Display Color
Select the data line background color for the alarm.
Background Color
Select the data line background color for the alarm.
Blink
Select the blink and blink speed. You can choose different alarm
blink settings for the [Display Color] and [Background Color].
There are cases where you can or cannot set
Blink depending on the Display Unit and [Display] tab's [Display
Settings] area. 8.3.1 Setting Colors
Set whether to display the major and minor scale on the trend
graph's Y-axis. If so, choose the number of divisions.
The number of divisions can be set from 1 to 638 for Major Scale,
and from 2 to 638 for Minor Scale.