For the trigger bit's ON/OFF, leave an interval
longer than the communication cycle time*1 or display scan
time*2, whichever is longer.
-
After you turn ON the Trigger Bit Address, if a
screen change occurs before the drawing or erasing is complete, the
Trigger Bit Address does not turn OFF.
-
The only graphic data that can be stored is Bin
data. BCD data cannot be used.
-
If the graphical data to be stored is outside the
range, it will default to zero.
-
When you set the display unit's orientation to
[Portrait] and use the [Draw Action] of the trigger action, the
data of the coordinate stored in [Mode] is different from the
coordinate point specified in the [Call Position of Screen to
Clear].
Please match the coordinates set to the [Call Position of Screen to
Clear] with the coordinate point of the display unit.
-
Display units except GP-4100 Series: Bottom-left
of the screen (0,0)
-
GP-4100 Series: Top-right of the screen
(0,0)
-
For more details, please refer to the
following.
3.8.1 Restrictions
for Screen Display
-
For the color attribute's background color, if
you designate "Black + Medium Speed Blink" or color code 255, the
background color will become transparent.
-
The following shows actions which occur
immediately after a screen is changed or power is turned ON.
O: Operation is performed immediately after
the screen is changed, or the power is turned ON.
X: Operation is not performed immediately after the screen is
changed, or the power is turned ON.