Adds the device/PLC settings. Use this setting when one display
is communicating with multiple devices/PLCs.
Select [Manufacturer], [Series], and [Port].
Deletes the specified device/PLC.
Changes the settings of the device/PLC.
Displays the settings of the currently specified
devices/PLCs.
Manufacturer
Displays the currently specified device/PLC maker.
Series
Displays the currently specified device/PLC series name.
Port
Displays the connection port of the currently specified
device/PLC.
Text Data
Mode
Displays the text data mode of the currently specified
devices/PLCs.
Change
When the [Change Text Data Mode] dialog box is displayed, you
can change the text data mode. Normally the text data mode is
specified according to each device/PLC.
Data in Device Addresses
Select the data device storage order from [Store from Top Data]
or [Store from Last Data].
Storing the text "ABCDE"
String Data Mode 1
String Data Mode 3
LH/HL Storage
Select the data storage order to specify in one word (16 bits)
from [LH Order] or [HL Order].
Storing the text "ABCDE"
String Data Mode 1
String Data Mode 2
Double Word LH/HL Storage
Select the data storage order to specify in two words (32 bits)
from [LH Order] or [HL Order].
Storing the text "ABCDE"
String Data Mode 1
String Data Mode 5
Text Data Mode
Displays the number associated with the Text Data Mode storage
order.
Select
Select the text data mode to be used.
Configure the settings according to the device/PLC. The settings
differ depending on the series. See "GP-Pro EX Device Connection
Manual." It is recommended to keep the default settings for
[Timeout], [Retry], and [Wait to Send].
Set this according to each device/PLC.
Allowable Number of Devices/PLCs
Displays the number of connectable units according to the type
of the display unit specified.
Add Device
Each time you click the [Add Device], one device/PLC is
added.
Increase Allowable Number of Devices/PLCs
When Yamatake Corporation MODBUS TCP Master is selected for the
device/PLC, this selection appears. Click this button and the
[Increase Allowable Number of Devices/PLCs] dialog box appears.
The number of connectable units can be expanded to 64 when the
[Increase allowable number of Devices/PLCs] check box is
selected.
Delete Device/PLC
Deletes the device/PLC settings.
Device Name
Set the name of a device/PLC characters from 20 to 10
(single-byte).
-
Do not duplicate the device name.
-
You cannot use a space and the following
symbols.
+ - * / = % & ^ | \ : . , †# ? @ [ ] < >
Device/PLC Settings
Set individual settings as needed according to the device/PLC.
Click the button to display the [Individual Device Settings] dialog
box.
Device ID
When using Indirect Device, and the series in the [Individual
Device Settings] dialog box match the device/PLC, use this field to
identify the device from 1 to 128.
Make sure you do not duplicate the Device ID with other indirect
devices in the same driver. If the Device ID is duplicated, the
warning icon appears
beside the field.
Add Indirect Device
Set up the Indirect Device feature. Click this button to add a
new indirect device to the list. You can add up to 64 indirect
devices.
Indirect Device Name
Set the name of the indirect device with up to 20 single-byte
characters (or 10 double-byte characters).
-
Do not duplicate device names.
-
The name cannot include a space or any of the
following symbols.
+ - * / = % & ^ | \ : . , †# ? @ [ ] < >
Device ID Address
When using indirect devices, the value in the Device ID Address
identifies the device ID of the device/PLC to communicate with. You
can only use the internal device addresses (LS area/USRS area).
Initial ID
Right after the display unit is turned ON and the value in the
[Device ID Address] is 0, use this field to specify which
device/PLC to use from 1 to 128.
Update Indirect Device
Settings
Displays the [Update Indirect Device Settings] dialog box. If
you change individual device settings after changing indirect
devices, use this dialog box to update selected indirect devices
with the new device/PLC settings.
Indirect Device Configuration
Displays the [Indirect Device Configuration] dialog box. Use
this dialog box to check the association between indirect devices,
devices/PLCs, and device IDs.