A.1.1.4 LS9000 Area (Direct Access Method)
The following lists the data contents stored in the LS9000
Area.
Display Unit Internal Address
|
Description
|
Introduction
|
H System Variable
|
LS9000 to
|
Display Historical Graph Data
|
Historical data numbers and data values
|
—
|
LS9100 to
|
Script Process
|
Script error code
|
—
|
LS9200 to
|
CSV Data Transfer Feature
|
Number and file number of CSV data files transferred by the
Condition Name Search Feature
|
—
|
LS9210 to
|
Reserved
|
Reserved
|
—
|
LS9220 to
|
LS9230 to
|
VM Unit serial mouse feature
|
Serial mouse touch state and coordinates
|
—
|
LS9235 to
|
Touch Coordinates
|
Touch coordinates on display unit screen
|
—
|
LS9240 to
|
Reserved
|
Reserved
|
—
|
LS9260 to
|
LS9270 to
|
LS9280 to
|
LS9290 to
|
LS9300 to
|
Security feature
|
Security Level
|
—
|
LS9310 to
|
Day of the Week
|
Day of the Week
|
#H_CurrentDayofTheWeek
|
LS9320 to
|
Reserved
|
Reserved
|
—
|
LS9330 to
|
LS9350 to
|
RGB 2ch Serial Mouse Feature
|
Touch state and coordinates of RGB unit serial mouse
|
—
|
LS9370 to
|
Reserved
|
Reserved
|
—
|
LS9400 to
|
Communication Cycle Time
4 drivers x 32 devices*2
|
Communication cycle time of device/PLC
|
[PLC*]#H_DriverCycleTime *1
|
LS9528 to
|
Reserved
|
Reserved
|
—
|
LS9550 to
|
Communication Scan ON/OFF Control
4 drivers X 32 devices*2
|
Device/PLC communication scan ON/OFF
|
[PLC*]#H_ScanOffControl
|
LS9558 to
|
Reserved
|
Reserved
|
—
|
LS9560 to
|
Communication Scan ON/OFF Status
4 drivers X 32 devices*2
|
Device/PLC communication scan status
|
[PLC*]#H_ScanOffStatus
|
LS9568
|
Reserved
|
Reserved
|
—
|
LS9800 to LS9815
|
Alarm Polling Cycle Information
|
Actual measured polling time and average time of each block when
extended alarm is enabled
|
—
|
LS9920 to
|
Reserved
|
Reserved
|
—
|
LS9930 to
|
LS9940 to LS9943
|
LS9944
|
LS9946
|
LS9950
|
Reserved
|
Reserved
|
—
|
LS9970 to LS9999
|
Details About Each Address
In the [Historical Trend Graph] part, select
the [Display Historical Data] check box to display the data numbers
and values for the oldest and newest data on the graph display
area.
19.8.3 Display Historical
Data
The following data is stored in Script
process area.
Stores the number and the file number of CSV
data transferred by the Condition Name Search Feature. The search
is only possible when the search string is a perfect match for the
condition name.
Spaces indicate different file names and can cause errors. When
data transfer is completed, the status and number of transferred
files displays. The last transferred file numbers are written in
the GP internal device Special Areas LS9200 and LS9201. (The
Special Areas are read-only.)
Using DVI/VM unit, this feature stores the
touch status and the touch coordinates when sending the touch
coordinates to a PC by serial communication.
28.10.7.4 Emulate Touch
Output
Stores the touch coordinates on a display
screen.
The display coordinate range depends on the
display unit's panel resolution. The display coordinate range is
fixed, no matter if you set up the display unit for portrait or
landscape orientation. When using portrait orientation, you cannot
store Y coordinates outside the following range.
-
The following operations do not store
coordinates, even if touch is involved
-
Offline Mode Operations
-
Screen Data Transfer Operations
-
System Menu Operation
-
Brightness/Contrast Control Bar Operations
-
Depending on the model, even if you touch
outside the display area, there are cases where the value is
retrieved. In such cases, the retrieved value will be outside the
display range.
-
When touch is not calibrated correctly, the
retrieved value may be out of range.
-
When two points are touched at the same time,
the centerpoint between those coordinates will be stored.
-
When using GP-Viewer EX, you cannot retrieve
touch coordinates.
-
When communication type is only Memory Link
with Ethernet Multilink, the master display unit coordinates are
stored.
-
When holding down a touch area, then sliding
the touch out of range, the touch condition turns OFF at the moment
touch goes out of range.
For WinGP, touch remains ON despite going out of range.
In such cases, the area's final touch coordinates are stored.
-
The following positions are the starting
coordinate point when a display unit's orientation is set to
[Portrait].
-
Display units except GP-4100 Series:
Bottom-left of the screen (0,0)
-
GP-4100 Series: Top-right of the screen
(0,0)
-
For more details, please refer to the
following.
3.8.1 Restrictions
for Screen Display
When bit 0 of LS9300 toggles from OFF to ON,
the security level stored in LS9301 will be changed to 0.
After the Security Level Clear occurs, return LS9300's 0 bit to
OFF. (LS9301 is read-only.)
Also, it stores the current security level
and the security level of the screen to be displayed
LS9301 and LS9302 are read-only. When there
is a password request in LS9302, the security level is stored and
the value returns to 0 when the password input is complete.
Stores the current value of the day of the
week. The day is calculated from the Year, Month, and Day of the
display unit's onboard IC (RTC) clock. The values stored in LS9310
are as follows.
Numeric Value
|
Description
|
0
|
Sunday
|
1
|
Monday
|
2
|
Tuesday
|
3
|
Wednesday
|
4
|
Thursday
|
5
|
Friday
|
6
|
Saturday
|
After 7
|
Unused
|
Updates are performed when the IC clock date is changed. Because
the writes do not occur regularly, when parts change in this area,
this area is not updated until the IC clock date changes.
When the RGB unit is set to display 2
channels at the same time and is sending the touch coordinates to a
PC by serial communication, it stores the touch status and
coordinates.
28.10.7.4 Emulate Touch
Output
Stores polling cycle time (in milliseconds)
of the configured Device/PLC
5.3.13 System Settings
[Peripheral List] Settings Guide
Controls whether to run or stop the
communication scan with the configured Device/PLCs.
5.3.13 System Settings
[Peripheral List] Settings Guide
Stores the communication scan status of the
configured Device/PLC
7.3.2 Procedure -
Confirming the Communication State
Stores the actual measured polling time and
average time of each block when extended alarm is enabled. Also
sets the Polling Time Exceeded bit to 1 when the actual polling
time exceeds the configured time.
20.10.1.2
Alarm Settings (Block 1) - Bit Monitoring
|