Data Type
When [Word Address] is selected, set the Data Type. Select [16
Bit Bin], [16 Bit BCD], [32 Bit Bin], or [32 Bit BCD].
Sign +/-
When [Word Address] is selected, defines negative number support
for display data. Set up when you want to display negative values.
Negative values are handled using 2's Complement.
This is available when the [Data Type] is [16 Bit Bin] or [32 Bit
Bin].
Area Specification
Select a method of specifying the minimum and maximum values of
[Input Range] and the Start and
End of [Angle Range] from [Constant] or
[Address].
Specify a fixed constant in the Min/Max, Start/End. (Direct
Specification)
Specify the address where the Min/Max, Start/End values are stored.
(Indirect Specification)
-
Do not change values in [Input Range] or [Angle
Range] from the time the control address trigger is turned ON
untill the the Display Unit turns ON the ACK bit. If a value is
changed, the animation may be displayed in an illegal place.
-
When [Address] is selected, animation will stop
if a communication error occurs with the specified device/PLC. The
animation starts again when the communication error is
recovered.
-
When [Address] is selected, an error message is
shown if the specified device/PLC is not connected and the objects
are not displayed.
Control Address
When [Address] is set in the [Specify Range], set the address to
control the input range or the angle range. Use a sequence of 2
Words from the specified address.
When Bit 0 (trigger bit) is turned on, start
reading device address values of the Max, Min, Start, and End.

When the reading of device addresses has
successfully completed, Bit 0 (ACK bit) turns ON.
In the error status, the results of integrity
check of max and min values are stored. When the result doenot
match, the value "1" is stored and the display position will not
change.

-
When 32 bit device addresses are set to the
control address, the lower 16 bits will be enabled. Please enter
[0] for the upper 16 bits.
-
Confirm the ACK bit OFF and then turn off the
trigger bit. When the trigger bit is turned OFF, the ACK bit or the
error status will be cleared automatically. to turn the trigger bit
ON next time, make sure the ACK bit is OFF.
-
Even when the minimum/maximum values are not
matched, the ACK bit is turned ON when the reading of device
addresses are complete.
Value Range
Set up the range of values on the address. This corresponds to
the [Position Range]'s Start and
End values. If [Specify Range] is
[Constant], set a numeric value. If [Specify Range] is [Address],
set a word address.
-
When the [Word Address] is selected,
minimum/maximum values are read according to the [Data Type] and
[Sign +/-] settings. When the [Numeric Expression] is selected,
data is read as 32 Bit Signed data.
Specifies the start point from which it will
move.
Data Type
|
Sign +/-
|
Input Range
|
16 Bit Bin
|
Unsigned
|
0 to 65534
|
Signed
|
-32768 to 32766
|
16 Bit BCD
|
—
|
0 to 9998
|
32 Bit Bin
|
Unsigned
|
0 to 4294967294
|
Signed
|
-2147483648 to 2147483646
|
32 Bit BCD
|
—
|
0 to 99999998
|
Specifies the end point. The object does not
move any farther.
Data Type
|
Sign +/-
|
Input Range
|
16 Bit Bin
|
Unsigned
|
1 to 65535
|
Signed
|
-32767 to 32767
|
16 Bit BCD
|
—
|
1 to 9999
|
32 Bit Bin
|
Unsigned
|
1 to 4294967295
|
Signed
|
-2147483647 to 2147483647
|
32 Bit BCD
|
—
|
1 to 99999999
|
Position Range
Sets up the range of movement for the object (as an offset from
the original object location). If [Specify Range] is [Constant],
set a numeric value. If [Specify Range] is [Address], set a word
address.
Defines the start point for object
movement.
Defines the end point for object
movement.
Numeric Expression
When the [Numeric Expression] is selected, click
to display the
[Numeric Expression] dialog box. Set the details of the
expression.
Expression
Define the expression. You cannot type the expression.
Click inside the expression to select and define that
portion.
Type
Select the type of conditional expression: [Word Address] or
[Constant].
Sets up word addresses in the expression.
Enter the values that define how much to move
between 0 and 4294967295.
Data Type
Select the data type. If you set [Type] = [Word Address], select
[16 Bit Bin], [16 Bit BCD], [32 Bit Bin] or [32 Bit BCD]. If you
set [Type] = [Constant], select [Dec], [Hex] or [Octal].
Sign +/-
Defines negative number support for display data. Set up when
you want to display negative values. Negative values are handled
using 2's Complement.
This is available when the [Data Type] is [16 Bit Bin] or [32 Bit
Bin].
Operator
Set up an operator. +, -, /, *, &, |,
^, %, <<, or >>.
Unary Op.
Set up an Unary operator. Select -, ~ or None.
Address/Constant
Set up an address.
Expand
Enlarges the script Expression area.
Removes parentheses set up with
.
Adds parentheses around the selected portion of the
expression.
Moves the selected portion to the left side of the operator.
Moves the selected portion to the right side of the
operator.
Select Expression
Selects the entire expression.
Add Comparison
Adds a condition to the expression.
Copy
Copies and adds the selected expression.
Add
Adds a part of the expression. Please enter the address
manually.
Delete
Removes a portion of the expression. You cannot select and
delete the entire expression.