Configure settings to display alarm messages registered on a
Text Screen.
Monitoring Word Address
Set the word which contains the monitoring bit top address. When
the Monitoring Word Address is set, one monitoring bit is allotted
to each row of the text.
Words to Monitor
Set the number of words allotted for the Monitoring Bits from 1
to 32. Set the number according to the number of rows inputted in
the text.
When the device address is expressed as 32 bits, one address
contains two words.
Font
Set the font of the Alarm Message.
Font Type
Choose the font type from [Standard Font], [Stroke Font], or
[Image Font].
Stroke Font and Standard Font
You can specify the vertical and horizontal
dimensions of a character in bitmap fonts. When you magnify/shrink
characters, the outline may become rough or the letter may appear
compressed.
This is an outline font where the ratio of
the character height/width is fixed. The letters will have a smooth
outline even if you magnify/shrink them. However, this font uses
more disk space on the display unit.
Font Size
Select the text size. Each font type has a different size
range.
Size
Specify "Width x Height" between [8 x 8] to
[64 x 128] in 8 pixel units.
6 to 127
If you select [Automatically Adjust Text
Size], you can adjust the [Maximum Size] and [Minimum Size].
Fixed Size
Available when [Standard Font] is selected. You can choose
between 6x10 pixels, 8x13 pixels, or 13x23 pixels. This font
supports single-byte characters only.
When using 6x10 fonts, you cannot set the [Text Attribute] to
[Bold].
Image Font
Windows fonts are converted to bitmaps and used in display
parts.
Select Font
Select the font and define [Style], [Size], and [Font Set].
Depending on the font you selected, available [Style], [Size], and
[Font Set] will differ.
-
A proportional font cannot be selected.
-
When the [Input Multilanguage] is not set in
the common settings [Text Registration], characters of the image
font used in the text display will be automatically registered.
Once registered, you can check the content in the [Characters Used]
in the [Image Font] settings.
-
When the [Input Multilanguage] is set, define
the font for each table. When the [Font] dialog box opens, click
to define [Font name], [Style],
[Size], and [Character Set].

Data Border
Choose the ruled line of the Text Alarm Part from [Without Ruled
Line], [Show Border], or [Show Border + Horizontal Ruled Line].
Text Number
Set the text Number of the text to be displayed.
Constant/Address
Select the designation method of the text Number from [Constant]
or [Address].
Designate a set constant as the Text File
Number (Direct Specification)
Select an address that will store the Text
Number. (Indirect Specification)
Text Screen Number
Set the text Number from 1 to 8999.
Display Start Row
Designate the row of the currently active Alarms to start a
display from 1 to 512.
Display Rows
Set how many Alarm Message rows will display at maximum on one
screen from 1 to 50.
Display Characters
Set the maximum number of Alarm Message characters that can
display on one row from 1 to 100.
Show Blank Row
Specify whether to display any blank lines in the text as an
Alarm Message.
Scroll Feature
Set whether to use the scroll feature or not.
When the scroll feature is not used, touching the cursor moving
switch does not move the cursor to the messages out of the display
area, and the cursor disappears.