GP-Pro EX Device/PLC Connection Manual

OMRON Corporation

The following table lists the Omron PLCs, and drivers that are supported by GP-Pro EX.

For details about how to connect to the Display, click the hyperlink in the Driver column to open the manual PDF (portable document format) file for that driver.

Please refer to [Pass-Through Function Guide] after checking the system requirements in case to use the pass through function with GP-Pro EX.

Please refer to [Serial Multilink Guide] after checking the system requirements in case to use the serial multilink with GP-Pro EX.

note

Serial

Series

CPU

Link I/F

Driver

SYSMAC C

C200H

C200H-LK202

C120-LK201-V1

C/CV Series HOST Link

C200HS

C200H-LK201

C200H-LK202

C120-LK201-V1

Link I/F on the CPU unit

Peripheral port on the CPU unit

C500

C500F

C1000H

C2000

C2000H

C120-LK201-V1

C120-LK202-V1

C500-LK201-V1

C500-LK203

C1000HF

C500-LK201-V1

C500-LK203

C20H

C28H

C40H

Link I/F on the CPU unit

C20PF

C28PF

C40PF

C60PF

C120-LK201-V1

C120-LK202-V1

C120

C120F

C120-LK201-V1

C120-LK202-V1

CQM1-CPU11

Peripheral port on the CPU unit

CQM1-CPU21

CQM1-CPU41

CQM1-CPU42

CQM1-CPU43

CQM1-CPU44

CQM1-CPU41-V1

CQM1-CPU42-V1

CQM1-CPU43-V1

CQM1-CPU44-V1

RS232C port on the CPU unit

Peripheral port on the CPU unit

CPM1

CPM1A

CPM1A-V1

Peripheral port on the CPU unit

CPM1-CIF01

CPM1-CIF11

SRM1-C02

CPM2A

RS232C port on the CPU unit

CPM1-CIF01

CPM1-CIF11

CPM2C

Peripheral port on the CPU unit

Peripheral port on the CPM2C-CIF01

RS232C port on the CPM2C-CIF01

RS232C port on the CPM2C-CIF11

Terminal block on the CPM2C-CIF11

CQM1H-CPU11

Peripheral port on the CPU unit

CQM1H-CPU21

Peripheral port on the CPU unit

RS232C port on the CPU unit

CQM1H-CPU51

CQM1H-CPU61

Peripheral port on the CPU unit

RS232C port on the CPU unit

RS232C port on the CQM1H-SCB41

RS422A/485 port on the CQM1H-SCB41

SYSMAC a

C200HE-CPU42

C200HG-CPU63

C200HG-CPU43

C200HX-CPU64

C200HX-CPU44

C200HE-CPU42-Z

C200HG-CPU63-Z

C200HG-CPU43-Z

C200HX-CPU85-Z

C200HX-CPU65-Z

C200HX-CPU64-Z

C200HX-CPU44-Z

RS232C port on the CPU unit

C200HW-COM02-V1

C200HW-COM03-V1

C200HW-COM04-V1

C200HW-COM05-V1

C200HW-COM06-V1

C200H-LK201-V1

C200H-LK202-V1

C200HX-CPU34

C200HX-CPU54

C200HX-CPU34-Z

C200HX-CPU54-Z

C200HE-CPU32

C200HE-CPU32-Z

C200HG-CPU33

C200HG-CPU33-Z

C200HG-CPU53

C200HG-CPU53-Z

C200HW-COM02-V1

C200HW-COM03-V1

C200HW-COM04-V1

C200HW-COM05-V1

C200HW-COM06-V1

C200H-LK201-V1

C200H-LK202-V1

C200HE-CPU11

C200HE-CPU11-Z

C200H-LK201-V1

C200H-LK202-V1

SYSMAC CV

CV500

CV1000

CV2000

CVM1

CVM1D

CV500-LK201

Link I/F on the CPU unit

SYSMAC CS1

CS1G-CPU45

CS1G-CPU44

CS1G-CPU43

CS1G-CPU42

CS1G-CPU45H

CS1G-CPU44H

CS1G-CPU43H

CS1G-CPU42H

CS1G-CPU45-V1

CS1G-CPU44-V1

CS1G-CPU43-V1

CS1G-CPU42-V1

CS1H-CPU67

CS1H-CPU66

CS1H-CPU65

CS1H-CPU64

CS1H-CPU63

CS1H-CPU67H

CS1H-CPU66H

CS1H-CPU65H

CS1H-CPU64H

CS1H-CPU63H

CS1H-CPU67-V1

CS1H-CPU66-V1

CS1H-CPU65-V1

CS1H-CPU64-V1

CS1H-CPU63-V1

RS232C port on the CPU unit

CS/CJ Series HOST Link

Peripheral port on the CPU unit

CS1W-SCU21

CS1W-SCB21

CS1W-SCB41

SYSMAC CJ

CJ1G-CPU45

CJ1G-CPU44

CJ1G-CPU45H

CJ1G-CPU44H

CJ1G-CPU43H

CJ1G-CPU42H

CJ1M-CPU23

CJ1M-CPU22

CJ1M-CPU21

CJ1M-CPU13

CJ1M-CPU12

CJ1M-CPU11

CJ1H-CPU66H

CJ1H-CPU65H

RS232C port on the CPU unit

Peripheral port on the CPU unit

CJ1W-SCU41

SYSMAC CJ2

CJ2H-CPU64-EIP
CJ2H-CPU65-EIP
CJ2H-CPU66-EIP
CJ2H-CPU67-EIP
CJ2H-CPU68-EIP

RS-232C serial port on the CPU unit

CJ1W-SCU21
CJ1W-SCU21-V1

CJ1W-SCU31-V1

CJ1W-SCU41
CJ1W-SCU41-V1

CJ2H-CPU68

CJ2H-CPU67

CJ2H-CPU66

CJ2H-CPU65

CJ2H-CPU64

CJ2M-CPU15

CJ2M-CPU14

CJ2M-CPU13

CJ2M-CPU12

CJ2M-CPU11

RS-232C serial port on the CPU unit

CJ1W-SCU21-V1

CJ1W-SCU31-V1

CJ1W-SCU41-V1

CJ2M-CPU35

CJ2M-CPU34

CJ2M-CPU33

CJ2M-CPU32

CJ2M-CPU31

CJ1W-SCU21-V1

CJ1W-SCU31-V1

CJ1W-SCU41-V1

SYSMAC CP1

CP1L-MooDR-A
CP1L-MooDR-D
CP1L-MooDT-D
CP1L-MooDT1-D
CP1L-MooDT-A
CP1L-LooDR-A
CP1L-LooDR-D
CP1L-LooDT-D
CP1L-LooDT1-D
CP1L-LooDT-A

Option Board
CP1W-CIF01

Option Board
CP1W-CIF11

CP1H-XooDR-A
CP1H-XooDT-D
CP1H-XooDT1-D
CP1H-XAooDR-A
CP1H-XAooDT-D
CP1H-XAooDT1-D
CP1H-YooDT-D

Option board
CP1W-CIF01

Option board
CP1W-CIF11

CJ1W-SCU21
CJ1W-SCU21-V1

CJ1W-SCU41
CJ1W-SCU41-V1

CJ1W-SCU31-V1

SYSMAC CP1E

CP1E-NooDR-A
CP1E-NooDT-A
CP1E-NooDT1-A
CP1E-NooDR-D
CP1E-NooDT-D
CP1E-NooDT1-D

Internal RS-232C port on the CPU unit

Ethernet

Series

CPU

Link I/F

Driver

SYSMAC CS

CS1G-CPU45

CS1G-CPU44

CS1G-CPU43

CS1G-CPU42

CS1G-CPU45H

CS1G-CPU44H

CS1G-CPU43H

CS1G-CPU42H

CS1G-CPU45-V1

CS1G-CPU44-V1

CS1G-CPU43-V1

CS1G-CPU42-V1

CS1H-CPU67

CS1H-CPU66

CS1H-CPU65

CS1H-CPU64

CS1H-CPU67H

CS1H-CPU66H

CS1H-CPU65H

CS1H-CPU64H

CS1H-CPU63H

CS1H-CPU67-V1

CS1H-CPU66-V1

CS1H-CPU65-V1

CS1H-CPU64-V1

CS1H-CPU63-V1

CS1W-ETN01

CS1W-ETN11

CS1W-ETN21

CS/CJ Series Ethernet

SYSMAC CS1

CS1G-CPU45

CS1G-CPU44

CS1G-CPU43

CS1G-CPU42

CS1G-CPU45H

CS1G-CPU44H

CS1G-CPU43H

CS1G-CPU42H

CS1G-CPU45-V1

CS1G-CPU44-V1

CS1G-CPU43-V1

CS1G-CPU42-V1

CS1H-CPU67

CS1H-CPU66

CS1H-CPU65

CS1H-CPU64

CS1H-CPU63

CS1H-CPU67H

CS1H-CPU66H

CS1H-CPU65H

CS1H-CPU64H

CS1H-CPU63H

CS1H-CPU67-V1

CS1H-CPU66-V1

CS1H-CPU65-V1

CS1H-CPU64-V1

CS1H-CPU63-V1

CS1W-EIP21

CS/CJ Series EtherNet/IP

Sysmac CJ

CJ1G-CPU45

CJ1G-CPU44

CJ1G-CPU45H

CJ1G-CPU44H

CJ1G-CPU43H

CJ1G-CPU42H

CJ1M-CPU23

CJ1M-CPU22

CJ1M-CPU21

CJ1M-CPU13

CJ1M-CPU12

CJ1M-CPU11

CJ1H-CPU66H

CJ1H-CPU65H

CJ1W-ETN11

CJ1W-ETN21

CS/CJ Series Ethernet

SYSMAC CJ2

CJ2H-CPU64-EIP

CJ2H-CPU65-EIP

CJ2H-CPU66-EIP

CJ2H-CPU67-EIP

CJ2H-CPU68-EIP

CJ2M-CPU35

CJ2M-CPU34

CJ2M-CPU33

CJ2M-CPU32

CJ2M-CPU31

EtherNet/IP port on CPU Unit

CS/CJ Series Ethernet

CJ1W-ETN21

EtherNet/IP Port on CPU Unit

CS/CJ Series EtherNet/IP

CJ2H-CPU68

CJ2H-CPU67

CJ2H-CPU66

CJ2H-CPU65

CJ2H-CPU64

CJ2M-CPU15

CJ2M-CPU14

CJ2M-CPU13

CJ2M-CPU12

CJ2M-CPU11

CJ1W-ETN21

CS/CJ Series Ethernet

SYSMAC CP1

CP1H-XooDR-A
CP1H-XooDT-D
CP1H-XooDT1-D
CP1H-XAooDR-A
CP1H-XAooDT-D
CP1H-XAooDT1-D
CP1H-YooDT-D

CJ1W-ETN21

CS/CJ Series Ethernet

Temperature Controller

Series

CPU

Link I/F

Driver

THERMAC NEO

E5EN-ooooo-FLK

E5AN-ooooo-FLK

Terminal block on the controller

Temperature Controller CompoWay/F

E5EN-ooooo-FLK

E5AN-ooooo-FLK

E5CN-ooooo-FLK

E5GN-ooooo-FLK

Terminal block on the controller

THERMAC

E5AR-ooooooooo-FLK

E5ER-ooooooooo-FLK

Terminal block on the controller

In-Panel NEO

E5ZN-oooooo-FLK

Terminal block on the controller