| The QPJ-xxxxx-xxx 5.7 inch models shipping after November 1, 2004 have
been updated with a different memory chip. This change in memory chip
requires two files within QuickDesigner software to be replaced with the
following two files:
|
| |
|
| The two files are: |
| |
|
| 81001090.ild |
| 81001090.spg |
| |
|
| Please perform the following actions before downloading an application
from your QuickDesigner software:
|
| |
|
| Step 1: Unzip the two files into a temporary directory.
|
| |
|
| Step 2: Locate the directory in which you have installed your QuickDesigner
software and locate a subfolder named, "Panel".
|
| |
|
| The default software installation location is:
C:\quick\Panel |
| |
|
| Step 3: Remove and backup the existing two filenames that match the files
listed above from the "Quick\Panel\" directory. Save these files in
case you have a problem with this procedure. |
| |
|
| Step 4: Copy the two files listed above from the temporary folder
into the "Quick\Panel" Directory. These files are to replace the
existing (renamed) files and will work with both older QPJ revision units plus
the new units. |
| |
|
| Step 5: Verify you have completed the above steps properly by downloading a
very simple text screen or object to the QPJ unit. If the application
downloads without encountering any problems you should be able to
download your standard application as well. |
| |
|
| Warning: QuickDesigner is not supported in Windows XP or Vista. Downloading a QuickDesigner project with
an XP system may corrupt your HMI's firmware. |
| |
|
|
QPJ-2D100-L2P, QPJ-2D100-S2P |