The error messages displayed during Project Converter operation and the causes and solutions
are as follows.
The selected Device/PLC is unavailable for conversion. Change the Device/
PLC before conversion.
The selected device/PLC type is not supported by GP-Pro EX. Please select a device/PLC that is supported by GP-Pro EX in GP-PRO/PBIII for Windows and run the Project Converter again. For the information on devices/PLCs supported by GP-Pro EX, see "Convertible Communication Driver List".
How to change [Device/PLC Type] in GP-PRO/PBIII for Windows
1.
Select the [Device/PLC Type] icon in GP-PRO/PBIII for Windows's Project Manager.
2.
The [Change] dialog box is displayed. Select a [Device/PLC Type] you want to
change to. Always confirm the device address settings after changing a
[Device/PLC Type].
Cannot read the source Device/PLC file.
Cannot recognize the convert-from device model. In GP-PRO/PBIII for Windows, change it to a device type supported by GP-Pro EX and then execute Project Converter again. For the information on devices/PLCs supported by GP-Pro EX, see "Convertible Communication Driver List".
How to change [Device/PLC Type] in GP-PRO/PBIII for Windows
1.
Select the [Device/PLC Type] icon in GP-PRO/PBIII for Windows’ Project
Manager.
2.
The [Change] dialog box is displayed. Select a [Device/PLC Type] you want to
change to. Always confirm the device address settings after changing a
[Device/PLC Type].
The selected model is unavailable for conversion. Change the model.
The selected device/PLC type is not supported by GP-Pro EX. Please select a device/PLC that is supported by GP-Pro EX in GP-PRO/PBIII for Windows and run the Project Converter again. For the information on devices/PLCs supported by GP-Pro EX, see "Models Comvertible to GP3000 Series".
·How to change [GP Type] in GP-PRO/PBIII for Windows
1.
Select the [GP Type] icon in GP-PRO/PBIII for Windows’ Project Manager.
2.
The [Change] dialog box is displayed. Select a [GP Type] you want to change
to. Be aware that the GP may have different features before and after conversion.
Cannot read the model information file.
Cannot recognize the convert-from device model. In GP-PRO/PBIII for Windows, change it to a device type supported by GP-Pro EX and then execute Project Converter again. For the information on devices/PLCs supported by GP-Pro EX, see "Models Comvertible to GP3000 Series".
·How to change [GP Type] in GP-PRO/PBIII for Windows
1.
Select the [GP Type] icon in GP-PRO/PBIII for Windows’ Project Manager.
2.
The [Change] dialog box is displayed. Select a [GP Type] you want to change
to. Be aware that the GP may have different features before and after conversion.
Cannot read AGPCnv.cfg file.
Failed to load GP-Pro EX's AGPCnv.cfg file. Install GP-Pro EX again.
Cannot read the prw file.
Failed to read a GP-PRO/PBIII for Windows file (*.prw). Microsoft Windows
access authority may be set to the GP-PRO/PBIII for Windows file (*.prw).
Check the file properties in Explorer and check the access authority settings.
Cannot access the parts file.
Failed to read a GP-PRO/PBIII for Windows' Part file (*.PDB or *.BPD).
Microsoft Windows access authority may be set to the GP-PRO/PBIII for Windows'
Part file (*.PDB or *.BPD). Check the file properties in Explorer and
check the access authority settings.
Invalid extention.
An incorrect extension is designated in Project Converter's [Convert To]. Input a
correct extension (*.prx).