| Product Name |
Model |
Notes |
Cable/Adapter Connection |
| Cables |
USB Transfer Cable (2m) |
CA3-USBCB-01 |
USB host to host cable, for transferring data, such as screen data, between AGP3000 Series and a personal computer. |
AGP side: USB Type-A Host side: USB Type-A |
Ethernet Crossover Cable
(5m) |
HMI-CAB-ETH |
Directly connect via ethernet either the PC to the HMI for programming or the HMI to the PLC for communications. |
AGP side: RJ-45 Host side: RJ-45 |
USB Cable
(5m) |
FP-US00 |
USB host to host cable for the connection of peripheral equipment. |
AGP side:USB Type-A Host side: USB Type-B |
USB to Serial Converter Cable
(1m) |
CA6-USB232-01 |
Converts a USB port to a serial port. Use with modems |
AGP side:USB Type-A Host side: D-Sub 9pin female |
USB Front Panel Access Cable
(1m) |
CA5-USBEXT-01 |
Extension cable (1m) attaching USB port to front panel. |
- |
RS-232C to Open ended Cable
(5m) |
HMI-CAB-ST001 |
Connects AGP COM port with 9 open ended wires for connecting to 3rd party screw terminal devices. |
COM1, AGP side: D-Sub 9pin female
Host side: 9 open conductors |
RS-232C Cable
(5m) |
CA3-CBL232/5M-01 |
RS-232C cable (5m) connecting various hosts with an AGP unit. |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 25pin male |
RS-422 Cable
(5m) |
CA3-CBL422-01 |
RS-422 cable (5m) connecting various hosts with an AGP unit. |
COM2, AGP side: D-Sub 9pin male
Host side: Crimped Separated Cable |
RS-422 Cable
(5m) |
CA3-CBL422/5M-01 |
RS-422 cable (5m) connecting various hosts with an AGP unit. *6,7 |
COM1, AGP side: D-Sub 9pin female
Host side: Crimped Separated Cable |
RS-422 Cable
(5m) |
GP230-IS11-O |
RS-422 cable (5m) connecting various hosts with an AGP unit. Use with CA3-CBLCBT422-01 |
COM1, AGP side: D-Sub 9pin female
Host side: D-sub 25pin |
Allen-Bradley SLC/Contrologix Connection Cable |
HMI-CAB-ST52 (12ft) |
RS-232C Cable provides direct connection to Allen-Bradley's SLC5/03,
5/04, Contrologix and Compactlogix PLCs |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 9pin female |
| HMI-CAB-ST52-30X (30ft) |
| HMI-CAB-ST52-50X (50ft) |
Allen-Bradley Micrologix Connection Cable (15ft)
|
HMI-CAB-ST106 |
RS-232C Cable provides direct connection to Allen-Bradley's Micrologix PLCs |
COM1, AGP side: D-Sub 9pin female
Host side: 8pin circular DIN |
Mitsubishi PLC
A-Series
Connection Cable
(5m) |
CA3-CBLA-01 |
Cable (5m) provides direct connection to CPU of Mitsubishi Electric's PLC A Series |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 25pin male |
Mitsubishi PLC
Q-Series
Connection Cable
(5m) |
CA3-CBLQ-01 |
Cable (5m) provides direct connection to CPU of Mitsubishi Electric's PLC Q Series |
COM1, AGP side: D-Sub 9pin female
Host side: MiniDIN 6pin |
Mitsubishi PLC Q-Series Link Cable (5m) |
CA3-CBLLNKMQ-01 |
Cable (5m) connecting to Link unit of Mitsubishi Electric's PLC Q Series |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 9pin male |
Mitsubishi PLC FX-Series Connection Cable (5m) |
CA3-CBLFX/5M-01 |
Cable (5m) provides direct connection to CPU of Mitsubishi Electric's PLC FX Series |
COM1, AGP side: D-Sub 9pin female
Host side: MiniDIN 8pin |
Mitsubishi PLC FX-Series Connection Cable (1m) |
CA3-CBLFX/1M-01 |
Cable (1m) provides direct connection to CPU of Mitsubishi Electric's PLC FX Series |
COM1, AGP side: D-Sub 9pin female
Host side: MiniDIN 8pin |
Omron PLC SYSMAC Link Cable (5m) |
CA3-CBLSYS-01 |
Cable (5m) connecting to LINK unit of Omron's PLC SYSMAC |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 9pin male |
Siemens S7 MPI Cable (3.5m) |
ST03-A2B-MPI21-PFE |
Connects a Siemens S7-200 to AGP3000 series (except AGP3302B and AST3201). For additional information,
refer to App. Note 1164 |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 9pin male |
| Connects a Siemens S7-200 & S7-300 to the AGP3302B and AST3201. For additional information,
refer to App. Note 1164 |
COM2, AGP side: D-Sub 9pin
Host side: D-Sub 9pin male |
Siemens S7 MPI Cable (3.5m) |
GP3000-MPI21-PFE |
Connects a Siemens S7-200 CPU215+, S7-300, S7-400 to AGP3000 series (except AGP3302B and AGP3200). For additional information,
refer to App. Note 1164 |
COM2, AGP side: D-Sub 9pin
Host side: D-Sub 9pin male |
AGP Multi-Link Cable (5m) |
CA3-CBLMLT-01 |
Cable (5m) connecting when Multi Link (n:1) communication is done between various host and an AGP unit. |
COM2, AGP side: D-Sub 9pin male
Host side: Crimped Separated Cable |
AGP 2 port Adapter Cable (5m) |
CA3-MDCB11 |
Connects Mitsubishi PLC to the AGP using the 2 port adapter II (RS-422) *6,7 |
COM2, AGP side: D-Sub 9pin male
Host side: Crimped Separated Cable |
| 9-pin-to-25-pin RS-232C Conversion Cable |
CA3-CBLCBT232-01 |
Connects a standard RS-232C cable (GP Connector: D-sub 25-pin) to the AGP. *6,7 |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 25pin male |
| 9-pin-to-25-pin RS-422 Conversion Cable |
CA3-CBLCBT422-01 |
Connects a standard RS-422 cable (GP Connector: D-sub 25-pin) to the AGP. *6,7 |
COM2, AGP side: D-Sub 9pin male
Host side: D-Sub 25pin female |
| AGP3000H Connector Cable |
GP3000H-CBLH-10M |
AGP3000H |
Hard type/ without connector/ 10m |
| AGP3000H Connector Cable |
GP3000H-CBLHD-10M |
AGP3000H |
Hard type/ with connector/ 10m |
| AGP3000H Connector Cable |
GP3000H-CBLS-*M |
AGP3000H ("*" is changed with length
Example: GP3000H-CBLSD-3M) |
Soft type/ without connector/ 3m,5m,10m |
| AGP3000H Connector Cable |
GP3000H-CBLSD-*M |
Soft type/ with connector/ 3m,5m,10m |
| USB Serial (RS-232C) Adapter Cable (50 cm) |
CA6-USB232-01 |
COM1 |
For COM 1 Cable for connecting a modem (RS-232C) to the GP3000 (USB host) |
| DVI Cable (5m) |
FP-DV01-50 |
For outputing image signal from host to GP |
| DVI Cable (10m) |
FP-DV01-100 |
| DVI-RGB Cable |
CA7-CBLCVRGB-01 |
For converting DVI-A to RGB |
| USB Cable for RGB Input Unit (5m) |
CA9-USBAMB/5M-01 |
USB cable for RGB Input Unit touch panel operation (Host-Slave: Mini-B) |
| RGB Cable (4.5 m) |
FP-CV02-45 |
For outputing image signal from host to GP |
| Adapters |
COM Port
Conversion Adapter |
CA3-ADPCOM-01 |
Pin Conversion Adapter connecting COM2's communication option to COM1 port of a unit. |
COM1, AGP side: D-Sub 9pin female
Host side: D-Sub 9pin female |
| On-line Adapter |
CA4-ADPONL-01 |
Polarization adapter for use when connecting RS-422/485. For more information, see
App. Note 1167 and
App. Note 1168.*7 |
COM 2: AGP side: D-Sub 9pin male
Host side: D-Sub 9pin female |
Terminal Block
Conversion Adapter |
CA3-ADPTRM-01 |
RS-422 Terminal adapter 9-pin D-sub to screw terminals
*6,7 |
AGP side: D-Sub 9pin male
Host side: terminal block |
| Siemens COM Port Conversion Adapter |
CA3-ADPSEI-01 |
Adapter connecting with the connecter for SIEMENS Profibus when MPI connection with SIEMENS's PLC is done. *8 |
COM2, AGP side: D-Sub 9pin male
Host side: D-Sub 9pin female |
Mitsubishi PLC A,QnA,FX Series 2 port adapter II |
GP070-MD11 |
Interface unit using Mitsubishi Electric's PLC A/QnA/FX Series at the same time. *6,7 |
| AGP3000H Conversion Adapter |
GP3000H-ADPCOM-01 |
For interfacing with a RS-232C/RS-422/RS-485 serial interface
output (DSUB) |
RS-232C Isolation Unit |
CA3-ISO232-01 |
Unit for electrically isolating a serial interface signal from the GP internal current (RS-232C and RS-422
are switchable). |
RS-485 Isolation Unit |
CA3-ISO485-01 |
Unit for electrically isolating a serial interface signal from the GP internal current (RS-422 and RS-485
are switchable). |
| CF Card Adapter |
GP077-CFAD10 |
Adapter using CF card with a PC's PCMCIA slot. |
| Pin Jack Adapter |
GP077-SDAD10 |
Adapter for converting the audio output section to the AUX connector
to a pin jack |
CF Cards |
256MB |
CA3-CFCALL/256MB-01 |
Compact Flash card for AGP3000 Series to manage data, such as saving screens, logging and data backup. |
| 512MB |
CA3-CFCALL/512MB-01 |
| 1GB |
CA6-CFCALL/1GB-01 |
| 2GB |
CA8-CFCALL/2GB-01 |
| Function Expansion Memory |
GP3000-EXDM01 |
Memory used for expanding GP-Pro EX alarm and character table functions*15 |
| Video Mix Module |
GP2000-VM41 |
Supports up to 4 NTSC/PAL Video Camera inputs on the AGP3500T/AGP3600T Series. This VM Unit
(4ch, 32,000 colors) displays and captures video images. Also has an Analog RGB input/output (1ch each). |
| GP3000-VM01 |
The VM Unit (4ch, 262,000 colors) displays and captures video images. Also has a DVI-I (DVI/ Analog RGB)
input/output (1ch each). |
| DVI Input Unit |
GP3000-DVI01 |
For inputting RGB to GP <only for 15/12.1/10.4 inch TFT unit> |
| RGB Input Unit |
GP3000-RGB201 |
For displaying analog RGB (2 CH) on the GP3000 |
| Industrial HUB |
SPIDER8TX-PRO |
HUB for Industrial Ethernet (8 ports) NOTE: Not available in the Americas |
| Cutout Adapter |
10.4-inch TFTscreens AGP35xxT |
CA4-ATM10-01 |
Adapter required for installing a 10.4-inch display unit (TFT) in the mounting hole of GP2500 for a 10.4-inch display unit (TFT) |
| Modbus Plus USB Gateway |
XBTZ-GUMP |
Expansion Unit to provide a bridge between the USB connector on an AGP3000 series to a Modbus Plus network. |
| PROFIBUS Slave Unit |
CA5-PFSALL/EX-01 |
Expansion Unit for connecting an AGP to a PROFIBUS network or communicating with a PROFIBUS-DP master. |
| DeviceNet Slave Unit |
CA6-DNSALL/EX-01 |
Expansion Unit for connecting an AGP to a DeviceNet network or communicating with a DeviceNet master. |
| CC-Link Unit |
CA7-CCLALL/EX-01 |
Expansion Unit for connecting AGP to a CC-Link network or communicating with a CC-Link master. (supports intelligent devices) |
| CANopen Slave Unit |
CA9-CANALL/EX-01 |
Expansion unit that enables participation of the GP3000 in
the CC-Link network and communication with the CC-Link master (supports intelligent
devices) *8 |
| CANopen Remote I/O Unit |
HTB1C0DM9LP |
HTB (Hybrid Terminal Block) |
Flex Network Modules *9 |
FLEX NETWORK 32-Point Input Sink Source Type I/O Unit |
FN-X32TS41 |
32-point sink-source shared I/O Unit. DC24V input signal can be connected. |
| FLEX NETWORK 16-Point Input Sink Source/16-Point Transistor Output Sink Type I/O Unit |
FN-XY16SK41 |
16-point input sink-source and 16-point transistor output sink mixed I/O unit. Both DC24V input signals and DC24V output (load current: 200mA max./1.6A/common) devices can be connected. |
| Flex Network 16-Point Input Sink Source/16-Point Transistor Output Source Type I/O Unit |
FN-XY16SC41 |
16-point input sink-source and 16-point transistor output source mixed I/O unit. Both DC24V input signals and DC24V output (load current: 200mA max./1.6A/common) devices can be connected. |
| Flex Network 32-Point Input Sink Source/32-Point Transistor Output Sink Type I/O Unit |
FN-XY32SKS41 |
32-point input sink-source and 32-point transistor output sink mixed I/O unit. Both DC24V input signals and DC24V output (load current: 200mA max./1.6A/common) devices can be connected. |
| Flex Network 8-Point Relay Output/1 Common Type I/O Unit |
FN-Y08RL41 |
8-point relay output (1 common) I/O Unit. Up to AC240V (1A) load current can be connected. |
| Flex Network 2-Channel Analog/Digital Conversion Input Unit |
FN-AD02AH41 |
Converts 2-channel analog signals to digital signals at 12-bit resolution. |
| Flex Network 2-Channel Digital/Analog Conversion Output Unit |
FN-DA02AH41 |
Converts 2-channel 12-bit digital signal to analog signal and sends output. |
| Flex Network 4-Channel Analog/Digital Conversion Input Unit |
FN-AD04AH11 |
Converts 4-channel analog signals to digital signals at 12-bit resolution. |
| Flex Network 4-Channel Digital/Analog Conversion Output Unit |
FN-DA04AH11 |
Converts 4-channel 12-bit digital signal to analog signal and sends output. |
| Flex Network Communication Cable |
FN-CABLE2010-31-MS (10m) |
Connects AGP units to the Flex Network modules. |
| FN-CABLE2050-31-MS (50m) |
| FN-CABLE2200-31-MS (200m) |
| CANopen Master Module |
CA8-CANLT-01 |
Module adds CANopen master functionality to the LT3000 series. |
EXM Modules *10 |
EXM 8-Point Input Module |
EXM-DDI8DT |
8-point sink-source shared I/O Unit |
| EXM 16-Point Input Module |
EXM-DDI16DT |
16-point sink-source shared I/O Unit |
| EXM 8-Point Relay Output Module |
EXM-DRA8RT |
8-point relay output sink type I/O unit |
| EXM 16-Point Relay Output Module |
EXM-DRA16RT |
16-point relay output sink type I/O unit |
| EXM 8-Point Sink Output Module |
EXM-DDO8UT |
8-point transistor output sink type I/O unit |
| EXM 16-Point Sink Output Module |
EXM-DDO16UK |
16-point transistor output sink type I/O unit Accepts 20-Pin connector,
CA6-EXMCNHE20P-01 or equivalent, sold separately |
| EXM 8-Point Source Output Module |
EXM-DDO8TT |
8-point transistor output source type I/O unit |
| EXM 16-Point Source Output Module |
EXM-DDO16TK |
16-point transistor output source type I/O unit Accepts 20-Pin connector,
CA6-EXMCNHE20P-01 or equivalent, sold separately |
| EXM 4-Point Input / 4-Point Output Module |
EXM-DMM8DRT |
4-point input sink-source and 4-point relay output |
| EXM 2-ch Analog Input Module |
EXM-AMI2HT |
2-ch analog input unit |
| EXM Thermocouple Pt100 Input / 1-ch Analog Output Module |
EXM-ALM3LT |
2-ch temperature input / 1-ch analog output unit |
| EXM 2-ch Analog Input / 1-ch Analog Output Module |
EXM-AMM3HT |
2-ch analog input / 1-ch analog output unit |
| EXM 1-ch Analog Output Module |
EXM-AMO1HT |
1-ch analog output unit |
| EXM 20-pin Ribbon Cable Crimp Connector |
CA6-EXMCNHE20P-01 |
Crimp Connector for EXM-DDO16UK and EXM-DDO16TK Output Modules (Accepts standard 3M 20 conductor ribbon cable,
sold commercially) (Qty 5) |