| Protocol
Download |
 |
 |
| > PLCs > HITACHI HIDIC
H Series |
 |
|
Please acknowledge the following terms of use before you use our download service. Download of any file
signifies your agreement to the terms of use.
Terms of Use
- Digital shall retain all intellectual property rights to the files that Digital provides for this service.
- You may download and use any file for non-profit purposes or for personal use within the organization to which you belong.
- Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file
that Digital provides for this service shall be prohibited.
- This download service is provided through the Internet. Please acknowledge that Digital provides no guarantee of the condition
at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
- Please use this service at your own risk.
- If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
- Files are subject to deletion, or modification of the contents or specifications without notice.
- Please confirm that the downloading file size completely accords
with the download file size shown.
- If the file sizes do not match, delete the file without decompressing and then download the same file once again.
|
| This update module consists of two table files used
in both the GP-PRO/PB III C-Package software and the Pro-Server with
Pro-Studio software. |
| |
| Title |
HITACHI HIDIC
H Series |
| File
Name |
HIDICH.exe |
| File
Size |
1,195KB |
| Table
file |
HITACHI HIDIC
H Series
- HIDICH.TBL
- HIDICH2.TBL |
| Revision
Details |
<Applicable
Software>
- GP-PRO/PB III for Windows Ver. 4.0 to Ver. 6.1 (C-Package01 & 02)
- Pro-Server with Pro-Studio Ver. 2.0 to Ver. 4.0
<Revision Details>
In the GP-PRO/PB III for Windows manual, the number of digits used for
Link Device address input is listed as "3", however, 4 digits
must be entered. As a result, when the #2 CPU Link Device's address is
entered as 3 digits, it becomes the setting for the #1 CPU Link Device.
*After installing this update module, the data entry method will revert
to the manual's "3" digits.
Important: Prior to
performing this update, if GP-PRO/PB III for Windows Ver. 2 or Ver. 3 data
has been converted for use with GP-PRO/PB III for Windows Ver. 4 to Ver.
6, there will be a "0" in the first digit. This will not cause
any problems and can be used as-is. If, however, this "0" is
deleted, the data will become the Link Register for the #1 CPU.
Performing this update will change the address display to the 3 digits
written in the manual, like the GP-PRO/PB III for Windows Ver. 2.0 to Ver.
3.0 screen data. |
|
Installation (The downloaded file is self-extracting.) |
| 1. |
Prior to installing
this module, close all Windows applications |
| 2. |
Click on the filename
shown above and download the data to the
desired folder on your PC. |
| 3. |
Double-click on
the file to start the installation process.
Follow the installation instructions given
to complete the installation. |
| 4. |
After installation
is finished, open the destination folder
and check that the following files are present,
with the time stamps shown here.
- HIDICH.TBL 2002/09/12 19:46
- HIDICH2.TBL 2002/09/20 13:25 |
|
| Last Updated: November.9.2002 |
|