PLCs > Siemens AG SIMATIC S5 CPU Direct Driver

Please acknowledge the following terms of use before you use our download service. Download of any file signifies your agreement to the terms of use.

Terms of Use
  1. Digital shall retain all intellectual property rights to the files that Digital provides for this service.
  2. You may download and use any file for non-profit purposes or for personal use within the organization to which you belong.
  3. Reproduction, disclosure, re-publication, assignment, lease, decompilation, modification, falsification or reuse of any file that Digital provides for this service shall be prohibited.
  4. This download service is provided through the Internet. Please acknowledge that Digital provides no guarantee of the condition at the time of provision, the availability of access and the condition of use concerning this service before you use this service.
  5. Please use this service at your own risk.
  6. If any additional conditions such as service usage conditions are attached to the downloaded files, please comply with such conditions as well.
Notices:
  1. Files are subject to deletion, or modification of the contents or specifications without notice.
  2. Please confirm that the downloading file size completely accords with the download file size shown.
  3. If the file sizes do not match, delete the file without decompressing and then download the same file once again.
 Download

Note:

Precautions for adding a new driver onto Windows Vista/7
Precautions for adding a new driver at Daylight Saving Time

Title Siemens AG SIMATIC S5 CPU Direct Driver
Version Ver. 1.13.02
File Name SIES5CPU.exe
File Size 848KB
Applicable Software GP-Pro EX Ver. 1.10.000 or later
Pro-Server EX Ver. 1.10.000 or later
You can check your version by ”Help” function -> ”Version Info”.
Related Devices
  • Siemens AG SIMATIC S5 CPU series
Related Units
  • AGP3000 Series
  • AGP4100 Series (AGP4105: GP-Pro EX Ver.2.60.000 or later)
    (AGP4104: GP-Pro EX Ver.2.70.000 or later, Ethernet Multilink only)
  • GP4000M Series (GP-Pro EX Ver. 2.71.000 or later)
  • GP4000 (GP-Pro EX Ver. 3.00.000 or later)
  • IPC Series for WinGP (GP-Pro EX Ver. 2.00.000 or later)
  • General PCs for WinGP (GP-Pro EX Ver. 2.10.000 or later)
Device/PLC Connection Manual For details, please read the following
PDF:sies5cpu.pdf ( 358KB )

For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver. 1.13.02 (Nov. 30, 2011)
The following settings were added:
  • CPU945/946/947/948 are newly supported.
  • GP4000M Series is supported.
    * To use a GP4000M Series Ver. 2.71.000 or later of GP-Pro EX s necessary.
The following issues were corrected:
  • Possible failure to read correct data from IW32 and QW32 of 90U-115U series.
  • Incorrect addresses may be accessed if target PLCs are switched during communication.
  • A communication error may occur only once when returning from offline to online.

Installation (This file is self-extracting.)

  1. Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  2. Click on the above file name to download the data to desired folder.
  3. After the download to your PC is finished, double-click on the file's icon to start the installer program.
  4. After the installer starts, follow the instructions given on each screen.
  5. After installation, execute GP-Pro EX.
  6. After installation, click on the Device/PLC area's [Siemens AG] selection and select [SIMATIC S5 CPU Direct].
*
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Update History:

[Ver. 1.13.02] (Nov. 30, 2011)

The following setting was added:
  • CPU945/946/947/948 are newly supported.
  • GP4000M Series was supported.
    * To use a GP4000M Series Ver. 2.71.000 or later of GP-Pro EX is necessary.
The following issue were corrected:
  • Possible failure to read correct data from IW32 and QW32 of 90U-115U series.
  • Incorrect address may be accessed if target PLCs are switched during communication.
  • A communication error may occur only once when returning from offline to online.

[Ver. 1.12.01]

The following settings were added:
  • GP4105 was supported.
    * To use a GP4105 Ver. 2.60.000 or later of GP-Pro EX is necessary.
  • GP4104 was supported.
    * To use a GP4104 (Ethernet Multilink) Ver. 2.70.000 or later of GP-Pro EX is necessary.

[Ver. 1.11.01]

The following setting was added:
  • Support for Device Monitor.
    * Ver. 2.00.000 or later version of GP-Pro EX is necessary to use a Device Monitor.

[Ver. 1.10.01] (Dec. 26, 2006)

New

Last Updated : Nov. 30, 2011
Posted : Dec. 26, 2006

| Return to Top | | Back | HOME |


Protection of Personal Information | Trademark Acknowledgments | Terms of Use
© Copyright 2004-2012. Pro-face. All rights reserved.